7.5 Alarm configuration

This page is used to enable clock supervision, to define the information to be transmitted and the
destination server. One or more settings can be defined and configured as alarms.
The following information is displayed:
• Enable SNMP checkbox: enables monitoring of the clock from a SNMP manager.
• Community: A set of clocks defined by the user. All the clocks on the network must have
the same Community name.
• Enable SNMP Trap: If enabled, error messages are sent to the SNMP Manager(s)
automatically.
• SNMP Manager 1/2/3: IP addresses of servers receiving alerts from the clocks.
SNMP Manager redundancy increases the reliability of alerts.
• Synchronisation failure: This setting is used to detect synchronisation discrepancies with
the source (Sigma master clock).
• Reboot: This setting is used to detect a clock reboot.
• Temperature: This setting is used to warn that the temperature range has been exceeded
(variable temperature range).
• Manipulation: This setting is used to trigger an alert if a setting is changed manually on the
clock (using the "S" and "+" keys).
• Server access: This setting is used to trigger an alert if a user connects to the web server
of the clock.
• Authentication failure: This setting is used to trigger an alert if a user sends an incorrect
ID to the web server of the clock.
• Periodic Status: This setting is used to verify that the device is still working correctly
(in case alerts are "lost"). This verification is carried out at a set frequency.