VIII
– Adjusting the brightness
Brightness can be adjusted when the Style clock is in normal operating mode, i.e. when it is neither
in the configuration menu nor in the set time menu. The default brightness is level 2.
+
Hold down for 3 seconds
+
S
End of menu
IX
– Memory backup
Style clocks have a permanent backup feature which stores all of the configuration parameters and
display settings, even in the event of prolonged power failure.
X
– Technical specifications
• Synchronisation: RFC 2030 (SNTP V4) compliant, Unicast, Multicast or via DHCP
• Synchronisation status: colon flashes if the clock is synchronised; colon steady then
blackout if a clock is not synchronised
• Network connection: 10Base-T/100Base-TX
• Power supply: PoE (Power over Ethernet)
• Accuracy: ±0.1s with automatic changeover to summer/winter time
• Operating temperature: -5°C to +55°C
• Protection rating: IP30, IK02 (standard Style)
• Protection rating: IP55, IK02 (waterproof Style)
• Standards compliance: EN 60950, EN 55022 and EN 55024
The clocks in the Style range comply with Electromagnetic Compatibility Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC. These are class A products. In the domestic environment, these
products may cause radio interference, in which case the user must take the appropriate measures.
They are designed for a residential, commercial or light industrial environment. They are compliant
with the European standards in force.
26
+
+
Select light intensity
LUM 1: low intensity
LUM 4: high intensity
EN