seen in the oil return hose (3).
To start the delivery of oil, close the release
valve (5).
N O T E : Oil can circulate through the return
hose, even when the release valve is closed.
If the THAP...E is connected to a high-pressure
pipe or lexible pressure hose, the air must be
removed from the pipe or hose. Often this can
be done by slightly loosening the pipe or hose
connection on the application, until air free
oil emerges. After de-airing the pipe or hose,
retighten the connection.
To stop the THAP...E, open the release valve (5)
to release the oil pressure, then close the air
valve (6)

4.1 Protection device

Protection device (THAP E–PC1) must be itted
when connecting a high pressure pipe to a
THAP 300E or THAP 400E.