AVENTICS | ED05 | R414002533–BAL–001–AG
Assembling the ED05 pressure regulator
6.3
Assembling the ED05 pressure regulator on
a base plate
The base plate is available in various designs as an accessory
part. The illustration shows an example with a single base plate.
16
Abb. 5: Assembling the ED05 pressure regulator on a base plate
15 Base plate seals
16 M6 x 75 screws (EN ISO 4762, formerly DIN 912)
Missing seals and connections will lead to non-compliance
with the IP 65 protection class!
Liquids and foreign objects could penetrate the device and
plug connections and destroy the electronics.
Use plug connections with the IP 65 protection class.
Make sure that the seals are integrated in the plug and
not damaged.
Make sure that all plugs are inserted before starting the
system.
Make sure that the seals are integrated in the plug and not
damaged.
Make sure that all plugs are inserted before starting the
system.
NOTICE