84
AVENTICS | ED05 | R414002533–BAL–001–AG
Technical data
Tabelle 12:
Pneumatics
Reproducibility
Hysteresis
Tabelle 13:
Electronics
Supply voltage
Admissible harmonic content
Power consumption
Input current resistance (set point)
Input voltage resistance (set point)
Current output (actual value), external working
resistance
Voltage output (actual value), external working
resistance
Switch output
Tabelle 14:
Standards and directives complied with
2004/108/EC
ISO 4414:2010
EN 61000-6-2
EN 61000-6-4:2007
"Electromagnetic compatibility" (EMC directive)
Pneumatic fluid power - General rules and safety requirements for systems
and their components
"Electromagnetic compatibility" (interference immunity for industrial
areas)
"Electromagnetic compatibility" (interference emission for industrial
areas)
Reproducibility
0.03 bar
(0.43 psi)
Hysteresis
< 0.06 bar
(< 0.87 psi)
24 V DC (±20%)
Only use a power pack with safe isolation for the
power supply
5%
Max. 1.3 A
Supply voltage switched on: 100 Ω
Supply voltage switched off: > 3 MΩ
Supply voltage switched on: 1 MΩ
Supply voltage switched off: > 3 MΩ
< 300 Ω
> 1 kΩ
24 V, I
= 100 mA
max.
Outlet pressure
At 6 to 10 bar
(87/145 psi)
Outlet pressure
At 6 to 10 bar
(87/145 psi)