Tabelle 11:
General
Dimensions (width x height x depth)
Weight
Operating temperature range
Storage temperature range
Control
Model
Permissible medium
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not
exceed 3 °C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS.
Protection class according to EN 60529/IEC529
Mounting orientation
Tabelle 12:
Pneumatics
Flow rate with 7 bar (101.5 psi) pilot pressure,
nominal pressure 6 bar (87 psi) and pressure drop
of 0.2 bar (2.9 psi)
Supply pressure
AVENTICS | ED05 | R414002533–BAL–001–AG
12 Technical data
62 mm x 136 mm x 65 mm
1.1 kg
0°C to 70°C
–20°C to +80°C
Analog
Poppet valve
Compressed air with quality class ISO 8573-1:2010
50 μm
0–1 mg/m
IP 65
(only when assembled and with all plugs assembled)
Preferred mounting orientation: vertical (see Fig. 3 on
page 61)
Any if used with dry and oil-free compressed air
The housing ventilation port must be open
1000 Nl/min
Supply pressure
Max. 7 bar
(101.5 psi)
Max. 11 bar
(159.5 psi)
3
Outlet pressure
At 0 to 6 bar
(0 to 87 psi)
At 0 to 10 bar
(0 to 145 psi)
83