Malfunction due to missing seals!
A drop in pressure may occur if the compressed air lines are
not connected to the compressed air connections (3, 4, 5)
using suitable seals (not included in the delivery contents).
Always connect the compressed air lines with suitable
seals.
1. Insert both the screws (14) (e.g. M6 x 75 in accordance with
EN ISO 4762, formerly DIN 912) in the two through holes in
the housing as shown in the illustration and tighten.
Tightening torque: 6 Nm
The inside diameter of the supply line must be at least
6 mm to attain the air flow rate stipulated in the
specifications.
2. Connect the supply line at inlet connection1 (4).
3. Connect the outlet line at outlet connection 2 (3).
4. Always connect a silencer or a line for restricted exhaust to
exhaust connection 3 (5).