AVENTICS | ED05 | R414002533–BAL–001–AG
Devices with two rectangular EN 175301-803 plugs:
Use a shielded cable to connect the X2A (10).
The shield must be connected with the "FE" plug connection.
Connect the lines to the rectangular X1S (11) and X2A (10)
plugs.
The ED05 pressure regulator can now be supplied with
voltage and controlled with a set point.
As the 0 V lines are connected at the X1S and X2A
connections, the correct polarization for all plug
connections must be ensured. A short circuit will result if
the supply voltage or set point voltage has a reversed
polarization.
For devices with two rectangular plugs controlled via a
potentiometer:
Connect the cables at the rectangular X2A plug as in the
1
illustration on the left.
2
3
The ED05 pressure regulator can now be supplied with
voltage and the set point set on the potentiometer.