Risk due to incorrectly mounted device!
An incorrectly mounted device may result in uncontrolled
movements that could damage other system parts.
Make sure that the device is securely fastened.
If using a base plate, mount it in a control cabinet or on a
mounting plate.
A vertical mounting orientation is preferred for the ED05
pressure regulator.
13
Abb. 3: Mounting orientation
13 Vertical axis
The device can be mounted in any orientation if the compressed
air is dry and oil-free.
Malfunction caused by closed housing ventilation port!
If the housing ventilation port is closed, there is no
atmospheric equalization and the characteristics curve
will change.
Ensure that the air can circulate freely through the
housing ventilation port (6).
Never operate the device in an atmosphere containing oil.
Assembling the ED05 pressure regulator