WARNING AND ERROR MESSAGES

9.1

Salt concentration too low or too high

When the salt concentration is within acceptable limits , the salt gauge will rise to a point within the ticked
(
) zone.

9.1.1 Salt concentration too low

Below a salt concentration of 1 g/litre, the cell will stop producing Chlorine and the message NO
CELL is displayed at the bottom of the LCD screen.
!
IMPORTANT
A low salt warning could be triggered by excessive build up of scale on the electrodes rather than a
real lack of salt. In the event of a low salt warning, check that the electrodes are clean and check the
salt concentration with a suitable tester in case of doubt.
A faulty temperature sensor could also cause a low salt warning

9.1.2 Salt concentration too high

At a salt concentration above 10.0 g/litre, the cell stops producing Chlorine and the icon
the right of the LCD screen. The high salt icons blink continuously and the message HIGH SALT or SHRT
CELL is displayed at the bottom of the screen.
The salt concentration is lowered by renewing a volume of pool water.
TRAITEMENT DE L'EAU
Low salt, the gauge is below the ticked range. The word 'Low' and
a salt shaker appear:
Fixed if the salt concentration is between 2 and 3 g/litre
Blinking if the salt concentration is bewteen 1 and 2 g/litre
High salt, the gauge is above the ticked range. in addition:
between 5.5 and 6.5 g/litre, the message "High" is displayed.
between 6.5 and 8.0 g/litre, the icon is displayed.
Above 8.0 g/litre, both the message and the icon blink.
2021/02 - Indice de révision : E - Code : 29650