4.7.1
Connection of the various components to the electrical panel
Remove the cover from the compartment containing the terminal connections.
Pass the connection cables through the cable glands located below the connection points.
1.
Temperature sensor (White)
2.
Flow switch (Blue)
3.
Acid dosing pump (Red)
4.
pH sensor
5.
Redox sensor
6.
Dosing pump power
N/LN =
Neutral
N = neutre de l'alimentation
N - Dosing pump power neutral
pompe doseuse
LN2 = Permanent
live (mandatory
with acid dosing)
LN2 = phase de l'alimentation
N - Dosing pump power phase
pompe doseuse
The cell is connected to the panel with cables fitted with quick fit connectors (cable length approx. 3.60 m).
The two tabs keep each pair of connectors correctly assembled with respect to each other. Check that they
are firmly connected by pulling lightly on each connector.
TRAITEMENT DE L'EAU
Serial ports, modem or
Earth
computer
LN2 = Live
slaved to
filtration
(dry contact = EES output is
unchanged is no voltage is
detected at the contact)
acid dosing
pump
Cover panel
Flow
switch
2021/02 - Indice de révision : E - Code : 29650
Cell
Cell
Water
T°C
sensor
+ pole
- pole
55/80