the casing.
Put the transparent cover back in position.
Check for leaks and leave the pump running in manual mode for 10-20 minutes in order to release the
air in the system.
10.5

Manual dismantling and descaling of the cell

If filtration is stopped, force it on for approximately one minute so that water flows through the cell in case
acid was just injected.
Isolate the by-pass loop on which the cell is mounted by completely closing the shut-off valves at the loop
inlet and outlet.
Disconnect the quick connectors of the cell power cables.
Unscrew the white barrel unions on either end of the cell, and remove the cell.
Screw the white blanking cap onto one of the cell openings, first making sure that the o-ring is correctly
positioned.
Turn the cell the other way round and stand it vertically on the white cap.
Pour white distilled vinegar or 10% Hydrochloric acid into the cell.
Wait until the scale is completely dissolved (stops frothing),
If scale is still present, empty the cell and repeat the procedure with vinegar or acid.
Rinse the cell with water.
Make sure that the o-rings are in position at either end of the cell and remount it. Put the installation back
into operational status (cell power cable, by-pass, valves, filtration timer)