NEVER MODIFY, SHORTEN OR EXTEND THE CABLES.
4.7.2 Wiring in the control panel
Principal: production of Chlorine by the cell must be slaved to operation of the filtration pump and circulation
of water through the flow sensor.
Disjoncteur magnéto-
Magnetotheral circuit breaker, pump
thermique pompe
N/LN1 = permanent neutral
LN2 = permanent live (panel and acid dosing pump)
LD2 = slaved live (cell)
*Nota bene: to avoid electrical disturbances when the pump starts and stops, the EES power cables
should not be in contact with those of the filtration pump: use a contactor with 4 power inputs/ outputs as
56/80
2021/02 - Indice de révision : E - Code : 29650
230 V ~
Contacteur*
Switch*
Disjoncteur, porte-
Circuit breaker, fuse housing or
fusible, ou sectionneur
switch
Bornier alimentation
EES panel power supply terminal
Horloge
Timer
Auto
TRAITEMENT DE L'EAU
coffret EES