Pre - Wiring; Filtration Unit Electrical Panel - BWT Soliflow Notice D'installation Et Conseils D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRE - WIRING

5.
CAUTION !
Wiring should be carried out according to the rules of the art. The Electrical panel should be installed
in a protected location close to Soliflow (HOUSE, garage, pool house)
5.1

Filtration unit electrical panel

Fuse 4 A
(Soliflow pump protection)
Differential circuit breaker
25 A - 30 mA
Fuse 10 A
(underwater light circuit)
Cable 1
Power supply 230V +
Earth
Cables 2 and 3 should be routed to the Soliflow connection box (see below).
Although cable 3 is only needed if an underwater light is installed, we recommend that you lay it now to facilitate
retrofitting of an underwater light at a later date.
The cable cross section should be 3 x 2.5
Connection
A :
Pump supply 230 Volts input.
BWT myPOOL
FILTRATION
Cable 2
230V + Earth
to the motor
for the motor power supply and 2 x 2.5
2
box
Neutral terminal
Earth terminal
Filtration unit pump timer
Cable 3
230 V to the underwaterlight
transformer
for the underwater light.
2
Connection to the
connector
1
Motor power supply neutral.
2
Earth.
3
Motor power supply live.
2021/01 - Indice de révision : I - Code : 26901