16
13 Model code
Series-no.
(determined by manufacturer)
Mechanical connection
2
= G1/2 A DIN 3852 (male)
8
= For separate temperature probe (TFP 100)
Electrical connection
6
= Male M12x1, 4 pole
only possible on output models "2" and "3"
(connector not supplied)
8
= Male M12x1, 5pole
only possible on output model " 5 "
(connector not supplied)
Output
2
= 2 switching outputs
only in conjunction with electrical connection type "6"
3
= 1 switching output and 1 analogue output
only in conjunction with electrical connection type "6"
5
= 2 switching outputs and 1 analogue output
only in conjunction with electrical connection type Anschlussart "8"
Measuring ranges
100 = -25 .. 100 °C (-13 .. 212 °F)
only for version with built-in sensor
150 = -30 .. 150 °C (-22 .. 302 °F)
only for version with separate sensor
Modification number
000 = Display in °C (determined by manufacturer)
400 = Anzeige in °F (determined by manufacturer)
Status: 29.01.2014
HYDAC ELECTRONIC GMBH
ETS 300
ETS 3 X X - X - XXX - 000
Part No.: 669651 E