General
When the appliance is not fitted with a power
cord with plug, the appliance may only be
connected by a qualified electician.
Please note:
The correct voltage for the appliance and the
connection value are shown on the rating
plate at the back of the oven. Always comply
with local regulations when connecting the
appliance.
U.K. only
To connect the appliance a fixed connection
has to be made. The wire which is coloured
green and yellow must be connected to the
terminal which is marked by the letter E or the
earth symbol
or which is coloured green,
or green and yellow. The wire which is
coloured blue must be connected to the
terminal which is marked by the letter N or
which is coloured black. The wire which is
coloured brown must be connected to the
terminal which is marked by the letter L or
which is coloured red. If the input of the
appliance acceeds 3 kW, the appliance has to
be connected to an outlet with a rated current
exceeding 13 Amp.
Electrical connection
230 V/240 V -50 Hz.
Make sure the appliance has an earth wire
connection. Use good quality cable for
connecting, e.g. H05RRF, 1,5 or 2,5 mm
with 3 or 5 cores, depending upon the
regulations.
With following colour code:
brown =
phase L
blue =
phase N
green/yellow = earth (
)
black =
neutral or phase
Depending upon the wiring diagram, you
can use the black cores for neutral or a
phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
Wiring diagrams
There is a label showing the wiring
diagrams on the underside of the
appliance.