► Insert the plug (3) into a properly installed
electrical outlet (4) matching the voltage and
electrical frequency stated on the charger's
rating plate.
The charger runs a self-test immediately after it
is plugged in. The charger LED (1) will glow
green for about 1 second, then it will glow red
briefly before going out. Once the LED goes out,
the self-test is complete and the charger is ready
to charge the battery.
► Position the power supply cord (2) so that it
will not be stepped on, tripped over, come in
contact with sharp objects or moving parts or
otherwise be subjected to damage or stress.
12.2
Charging
WARNING
■ STIHL batteries contain safety features and
devices which, if damaged, may allow the bat‐
tery to generate heat, rupture, leak, ignite or
explode. Never charge a malfunctioning, dam‐
aged, cracked, leaking or deformed battery.
For indoor use only. Keep the charger dry.
Protect it from rain, water, liquids and damp
conditions. Never insert a wet battery. Never
use a wet charger,
To charge the battery:
2
1
► Push the battery (2) into the charger (3) until it
stops.
The LED on the charger (4) glows green when
the battery is charging.
The LEDs (1) on the battery glow green and
show the state of charge.
When the LEDs on the battery turn off, the
charging process is complete and the charger
will shut itself off. The battery can be removed
from the charger.
► Disconnect the power supply cord from the
electrical outlet when the charger is not in use
for extended periods of time.
24
9.
3
4
A battery is not fully charged when it ships from
the factory. STIHL recommends that you fully
charge the battery before using it the first time.
Operate the charger indoors in a dry room. For
optimum performance, observe the recommen‐
ded ambient temperature ranges,
The battery heats up during operation of the
chain saw. If a hot battery is inserted into the
charger, it may be necessary for it to cool down
before charging starts. The charging process
begins only after the battery has cooled down
sufficiently.
Charging time depends on a number of factors,
including battery condition and the ambient tem‐
perature. For a complete list of approximate
charging times, see www.stihl.com/charging-
times.
12.3
Mounting the Charger on a
Wall
Before mounting, ensure that no electrical
cables, pipes or other service lines run in the wall
behind the charger.
To mount the wall charger:
b
2
1
c
a
► Mount the charger indoors in a dry room near
an electrical outlet.
► Sink the screws into a wall stud. Use appropri‐
ate screw-in wall anchors or other similar
mounting devices if an appropriate wall stud is
not available.
► Align the charger as shown above. Mount to a
wall with the following dimensions:
– a = minimum 18 in. (450 mm)
– b = minimum 3.9 in. (100 mm)
– c (for AL 101) = 3.0 in. (75 mm)
– c (for AL 301) = 3.9 in. (100 mm)
– c (for AL 500) = 4.7 in. (120 mm)
– d = 0.2 in. (4.5 mm)
– e = 0.4 in. (9 mm)
– f = 0.1 in. (2.5 mm)
12 Charging the Battery
25.8.
3
e
d
f
f
0458-022-8201-A