when the product is used at the same time as other
appliances that run on gas or other fuels. ● The regulations
laid down by local authorities must be strictly followed with
regard to the technical and safety measures to be adopted
for fume extraction. ● The extracted air must not be
conveyed through the same ducts used to extract the
fumes generated by the combustion of gas or other types
of fuels. ● Never use the product without the grille properly
installed!
ELECTRICAL CONNECTION SAFETY
● Disconnect the product from the mains. ● Installation
must be carried out by professionally qualified personnel
with knowledge of the regulations in force for installation
and safety. ● The manufacturer denies all liability to
persons, animals or property if the guidelines provided in
this chapter are not followed. ● By law, the product must
be earthed. ● The power cable must be long enough to
allow the product, built into the cabinet, to be connected to
the mains. ● The power cable must be long enough to
allow removal of the hob from the worktop. ● Do not use
power strips or extension cords. ● Check that the voltage
on the rating plate on the bottom of the product
corresponds to that of the domestic environment where it
will be installed. ● The earth cable must be 2cm longer
than the other cables. ● The temperature must not reach
50°C above room temperature anywhere along the cable.
● The product is designed to be permanently connected to
the mains; for this reason, make the connection to the
mains via an omnipolar switch in accordance with the
installation rules, which ensures complete disconnection
from the mains in overvoltage category III conditions, and
which is easily accessible after maintenance. ● Once
installation is complete, the electrical components must no
longer be accessible by the user. ● Please note! Do not
connect the product to the mains until the installation is
complete. ● Before connecting the product to the mains:
check the rating plate (on the bottom of the product) to
ensure that the voltage and power correspond to the mains
supply and that the power socket is suitable. If in doubt,
consult a qualified electrician.
● If the product is not equipped with a power cable, use
one with a minimum conductor section of 2.5 mm
power up to 5500 Watt; while for higher powers it must be 4
2
mm
).
● Please note! The interconnection cable must be
replaced by the authorised customer service representative
or by a person with similar qualifications.
the product is equipped with a Power
POWER LIMITATION:
Limitation function, which allows a maximum power limit to
be set (kw)
The setting must be made when the product is connected
to the mains or when the mains power itself is restored
(within the following 2 minutes). Size the electrical system
protection according to the selected Power Limitation level.
For the Power Limitation setting sequence, see the
Operation section of this manual.
The product can also be used in
WINDOWS KIT:
conjunction with a Window sensor KIT (not supplied by
the manufacturer). If the Window sensor KIT is installed
(only if used in DUCT-OUT mode), air extraction will halt
every time the window in the room, on which the KIT is
applied, is closed. The KIT must be electrically
connected to the device by qualified and specialised
technical personnel. The KIT must be certified
separately in accordance with the safety standards for
the component and its use with the device. Installation
must be carried out in accordance with current
regulations for domestic systems.
PLEASE NOTE: the wiring of the KIT to be connected
to the product must be part of a certified safety extra-
low voltage (SELV) circuit. The manufacturer of this
device disclaims all liability for any inconvenience,
damage or fires caused by defects and/or problems
associated with the malfunction and/or incorrect
installation of the KIT.
INSTALLATION SAFETY
● The electrical and mechanical installation must be
performed by qualified personnel.
● Before starting the installation: After unpacking the
product, check that it has not been damaged during
transport and in the case of problems, contact your dealer
or Customer Service, before proceeding with the
installation; Check that the purchased product is the right
size for the installation location; Check for accessories
inside the packaging (placed there for ease of transport,
such as bags containing screws, the warranty certificate,
etc.). Remove and keep them safe; Also check that there is
a power socket near the installation area
● Preparing the cabinet for installation:
• The product cannot be installed above cooling
appliances,
dishwashers,
machines and dryers; Create the cut-outs in the cabinet
before inserting the hob and carefully remove shavings or
sawdust.
The minimum distance between the hob and the wall must
be at least 50mm from the front, at least 50mm from the
sides and at least 500mm from the upper wall units.
NB: when designing the space, the kitchen manufacturer's
2
for
instructions must be followed.
• to optimise the recirculating installation, it is
recommended to create a slot in the plinth, in which to
insert a commercial grille.
• Important: use a single component adhesive sealant (S)
that can withstand high temperatures up to 250°; before
installation, the surfaces that need to be glued must be
thoroughly cleaned, removing all substances that may
compromise adhesion (e.g. release agents, preservatives,
grease, oils, powders, old adhesive residue, etc.); the
adhesive must be evenly spread along the entire perimeter
of the frame; after gluing, leave the adhesive to dry for
about 24 hours.
● Please note! Failure to install screws and fasteners in
accordance with these instructions may result in electrical
hazards.
13
heaters,
ovens,
washing