Type 1094 EV
Technical Data
6.5.1.
frequency inputs / gasoline pulses
The volumetric flow of the delivered gasoline is measured by the piston
meter, converted into a frequency-proportional clock signal by the
gasoline pump computer and switched to the frequency input of the
controller (Fig. 4: ).
In the controller this clock signal is processed as the actual value of
the volumetric flow of the gasoline.
High-level pulse:
3.4 V – 26 V
Low-level pulse:
0 V – +0,9 V
Input resistance:
> 10 kΩ
Max. input current:
5 mA
Min. pulse duration:
400 µs
Measurement rate:
1 measurement/0.75 s
Resolution:
1 Hz
Measuring range:
0 ... 51 l/min
Pulse rate:
Can be adjusted via manual control unit from
31 – 200 pulses/liter
5 V
Input
terminals
for gasoline
pulse
Fig. 4:
Frequency input of the controller Type 1094 EV
(1
The Jumper C0 (C03 for side 1 and C05 for side 2) can be used
to switch the input from "open emitter" to "open collector".
English
(1
Jumper
C03 / C05
Input to the
controller
GND
15