Burkert 1094 EV Manuel D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type 1094 EV
Technical Data
6.5.4.
Outputs / Motor contactor
The output for the motor contactor is activated by the controller for as
long as the proportional valve is open.
This contactor/relay switches the vacuum pump motor.
Furthermore, a overtravel time can be set for the vacuum pump (motor
contactor) for which the signal remains active. If the overtravel is set
to 0s, the motor contactor is not activated. This function is useful for
defective motors.
Load current:
0 ... 150 mA
Output voltage:
24 V DC
Number of outputs:
2 (1 output each for side 1 and for side 2)
Output
µController
Fig. 7:
Motor contact output of the controller Type 1094 EV
24 V
Connection
terminals
for motor
contactor
GND
6.5.5.
Operation as ac device at 230/115 V
A power supply unit was installed for the operation of the vapor
recovery 1094 EV. This power supply unit has the following data:
Manufacturer:
TRACO POWER
Designation:
Industrial Power Supply
Model:
TBL 030-124
Power supply voltage:
100 ... 240 V 50/60 Hz -15 % / +10 %
Max. power consumption: 0,5 ... 0,9 A
Output voltage:
24 V DC ±10 %
Max. output current:
1.25 A
Max. output power:
30 W
Fig. 8:
Control Type 1094 EV with 24 V power supply unit
English
17

Publicité

Table des Matières
loading

Table des Matières