Neonatal Unheated
Fitting Batteries (4 x AA type - batteries not supplied with
Mattress for LifeStart
LifeStart)
To fit or replace the batteries in the Timer, remove the Timer
Instructions for Use
Battery Tray underneath the Timer by pushing the tabs at each
side inward and then sliding out from the Timer. Fit 4 × AA type
batteries, observing correct polarity as indicated inside the
Battery Tray. Please change all four batteries at the same time
to avoid uneven discharge and possible damage caused by
Infection Control and Cleaning
leaking batteries. Replace the Timer Battery Tray by pushing
it in until it clicks and is therefore fully engaged.
Clean with care using a damp soapy cloth and/or disinfectant
wipes (pH neutral or alkaline).
• Where higher level of decontamination is required,
use Sodium Hypochlorite (bleach) solution or similar
Fitting the basket
(up to 10,000 ppm available Chlorine). After cleaning
with bleach solution, wipe down to remove residual
LSU003 and LSU003a series are both supplied with a basket. To fit
cleaning agent and dry.
the basket, slide the fitted bracket on the basket onto the Medirail.
Secure the basket using the Medirail thumb screw found at the
• Do not immerse in fluids.
bottom of the bracket.
• Do not process in an autoclave, steriliser or automatic
washer-disinfector.
• Do not use phenolic based products, abrasives or
harsh chemicals for cleaning.
Disposal
5. Accessories
Dispose of in line with local protocol.
Medirails are fitted to the LifeStart to enable the system to carry a range of medical
Safety
equipment in close proximity to the patient.
Attach the required accessories to the Medirails, ensuring that they are fully secure and
Contraindications
do not present an obstruction to other items or to the power outlets. The user must also
Avoid direct contact with mattress in circumstances where
ensure when attaching the accessories that they are not obstructing the ability to
patient's skin is compromised.
connect/disconnect the device. It is anticipated that the following accessories might be
Warnings
required to provide necessary treatment and support for the patient: gas cylinders,
neonatal warming system, suction system suitable for a newborn infant, air/oxygen
The user should carefully read the instructions for use before
blender, resuscitator (Inspire rPAP
using the equipment.
in Recommended Configuration.
This mattress should only be used with LifeStart
Do not use if there is any sign of damage. Ensure the surface
integrity of the mattress and replace if necessary.
This mattress is not sterile. Where necessary the user should
take appropriate precautions to protect the sterile field.
Consult Instructions for Use
This way up. The mattress must be
positioned with this symbol on top
The mattress may become damaged
or perforated by sharp objects or
instruments
Inspiration Healthcare Limited
W
inspiration-healthcare.com
™
Part Number
IHC-LSA060
). A recommended configuration is illustrated below
TM
.
TM
Catalogue number
Manufacturer
Date of manufacture
Serial number
217
9
Part Description
Neonatal Unheated Mattress for LifeStart
Do not use if package is damaged
Keep dry
Keep away from sunlight
Caution: Federal law restricts this device to
sale by or on the order of a physician
TM