Fitting Batteries (4 x AA type - batteries not supplied with
LifeStart)
Gasflasker
asflasker holdes på plads ved at fastg re gummibåndene på flaskeholderen ved hjælp af de medf lgende metalclips.
To fit or replace the batteries in the Timer, remove the Timer
Battery Tray underneath the Timer by pushing the tabs at each
side inward and then sliding out from the Timer. Fit 4 × AA type
batteries, observing correct polarity as indicated inside the
Battery Tray. Please change all four batteries at the same time
to avoid uneven discharge and possible damage caused by
leaking batteries. Replace the Timer Battery Tray by pushing
it in until it clicks and is therefore fully engaged.
Fitting the basket
Afdækning
LSU003 and LSU003a series are both supplied with a basket. To fit
Det er muligt at få en steril afdækning til enheden til brug på operationsstuer og f destuer for at bevare det sterile felt og forhindre
the basket, slide the fitted bracket on the basket onto the Medirail.
v æ s
k e i n d t r æ n
g e n . A f d æ k
Secure the basket using the Medirail thumb screw found at the
LifeStart , så alt påmonteret tilbeh r tildækkes. Den bl de, ikke vævede pude skal placeres over patientplatformen.
bottom of the bracket.
5. Accessories
Medirails are fitted to the LifeStart to enable the system to carry a range of medical
equipment in close proximity to the patient.
Attach the required accessories to the Medirails, ensuring that they are fully secure and
do not present an obstruction to other items or to the power outlets. The user must also
ensure when attaching the accessories that they are not obstructing the ability to
connect/disconnect the device. It is anticipated that the following accessories might be
required to provide necessary treatment and support for the patient: gas cylinders,
neonatal warming system, suction system suitable for a newborn infant, air/oxygen
blender, resuscitator (Inspire rPAP
in Recommended Configuration.
Ækvipotential jordforbindelse
En ækvipotential jordforbindelse på siden af enheden er n dvendig til test af elektriske kredsl b mv., hvilket kan være påkrævet
i h e n h o l d t i l l o k a l e b e s t e m m e l s e r . Læ s
Inspiration Healthcare Limited
W
inspiration-healthcare.com
n i n g e n a n v e n d e s v e d a t s i k r e , a t p l a s t e n o m h y g g e l i g t l ø f t e s o p o v e r p a t i e n t p l a t f o r m e n , o g d e r e f t e r o v e r
). A recommended configuration is illustrated below
TM
v e n l i g s t d e l o k a l e b e s t e m m e l s e r f o r a t a f g ø r e , o m d e t t e e r t i l f æ l d e t .
183