Repair
Replacing the pulley crosses
The pulley crosses are constructed identically on both sides. Therefore, we will only describe the procedure on the right side
here. Follow steps 2-9 for the left side as well.
Follow these steps when replacing a pulley cross:
1.
Remove the cover as described here: Removing the roof (Page 81)
2.
If the rope is present, secure the rope of the rope box. To do this, use the rope clamp and rope pulley from the envelope in the
document pocket. Install the rope stopping mechanism in reverse order to the removal of the rope stopping mechanism. The
procedure is described here: Removing the rope stopping mechanism (Page 89)
NOTICE
Danger of crushing by rope box
The rope is tensioned by a spring tension mechanism in the rope box. Avoid crushing and burns. Pull the cable down on
the cable clamp until the rope clamp is relieved. This allows you to remove the rope clamp on the rope box.
Figure 24
Rope stopping mechanism
3.
Loosen the four M6x16 half-round head screws and remove the cover plate from the jib.
Figure 25
Disassembly of the cover plate
94
Installation of the cable management system V1.6
A5E53160522-AC, 05/2024