1.
Measure 3.45 m from the cable outlet of the charging plug. Clean the area with the grease-dissolving cleaner and cloth. Wrap
the rubber adhesive tape
cable type. See the number of windings in the table. Cut off unneeded rubber adhesive tape.
Cable type
CHARX T2C-DC375-...ESBK001
EV-T2M4CC-DC250A-...
EV-T2HPCC-DC500A-...
RADOX HPC500 CCS2-...CC55/CC65
SEVS20-003(S)B_SEVD-02E-...
Figure 10
Wrapping tape around the charging cable
2.
Untie the knot at the end of the rope. Pull the rope through the hole of the absorber sphere
Figure 11
Absorber sphere
3.
Place the charging cable in a cable clamp. Place the rubber tape in the middle of the cable clamp.
Figure 12
Inserting the charging cable
Installation of the cable management system V1.6
A5E53160522-AC, 05/2024
overlapping around the charging cable
Specification
375 A uncooled
250 A uncooled
500 A cooled, Phoenix Contact
500 A cooled, Huber+Suhner
CHAdeMO 125 A
Installing the cable management
at this point. The number of windings depends on the
.
Number of windings
1
3.5
2
4
5