Télécharger Imprimer la page

Dometic BUTTNER MT LB 40 Instructions De Montage page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
EN   MT LB
Description of the device
Fig. 
on page 3
Table 1: Connections and controls
No.
Designation
1
N-BUS
2
N-BUS
3
4
AUX
5
GND
6
OUT
7
INPUT
8
9
ON
10
11
Table 2: Status LED
LED
Description
Green flashing
Battery charging.
Voltage higher than 12 V or 24 V (depending on the model).
Orange
Battery charging.
flashing
Output voltage lower than 12 V or 24 V (depending on the model).
Green
Battery completely charged, float mode.
Red flashing
Error occurred (see Troubleshooting)
Fig. 
on page 3
Table 3: Terminal block
PIN
Designation
1
D+ terminal
2
Sense +
3
Sense -
14
OFF
Remote
/
/
Description
Input for D+ signal of the alternator or ignition lock signal (terminal 15)
Signal (+) output voltage
Signal (-) output voltage
Description
N-BUS/CI-BUS connection 1
N-BUS/CI-BUS connection 2
Status LED
AUX connection
Connection to chassis or negative pole of the house battery
Connection to positive pole of house battery
Connection to positive pole of starting battery
Terminal block for signal cables
DIP switches for settings
Switch (ON/OFF/Remote control)
Torx key (accessory)

Publicité