NOTE 1: At 80 MHz and 800 MHz, the higher frequency range
applies.
NOTE 2: These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
a
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the RF generator is used exceeds the applicable RF
compliance level above, the RF generator should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as re-orienting
or relocating the RF generator.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable
and mobile RF communications equipment and the
NovaSure RF controller
The NovaSure RF controller is intended for use in the
electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the NovaSure RF
controller can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the NovaSure RF
controller as recommended in the following table, according to the
maximum output power of the communications device.

Recommended separation distance

Rated
Separation distance according to frequency of
maximum
output power of
transmitter
150 kHz to
W
80 MHz
0.01
0.12
0.1
0.37
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according
to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the
higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.

Cleaning and Sanitizing

The use of nonflammable agents for cleaning and sanitizing is
recommended. Flammable agents or solvents for cleaning or sanitizing
should be allowed to evaporate before use of the NovaSure system.
The NovaSure RF controller is not sterile. Cleaning should be done using
a mild detergent and water solution to wipe surface areas only. Do not
transmitter
m
80 MHz to
800 MHz to 2.7 GHz
800 MHz
0.12
0.37
1.2
1.2
3.7
3.7
12
12
immerse unit in liquid or introduce liquid into the cooling vents or RF
cable areas.
The NovaSure disposable device is a sterile disposable device for single-
patient use only.
• Do not use if the packaging is opened or damaged.
• Do not reuse or re-sterilize the disposable device.
Do not sterilize any component of the NovaSure impedance controlled
endometrial ablation system.

Parts List

Ordering information and related parts and accessories
Product Number
RFC2009
RFC2010
814002
814003
814004
814005
814009
814011
814015
814016
RFC2000-FS
815012
NS2013
NS2013KIT
0.23
0.74
300001
2.3
7.4

Warranty

23
Except as otherwise expressly stated in the Agreement: i) Equipment
manufactured by Hologic is warranted to the original Customer
to perform substantially in accordance with published product
specifications for one (1) year starting from the date of shipment, or if
Installation is required, from the date of Installation ("Warranty Period");
ii) digital imaging mammography x-ray tubes are warranted for twenty-
four (24) months, during which the x-ray tubes are fully warranted for the
first twelve (12) months and are warranted on a straight-line prorated
basis during months 13-24; iii) replacement parts and remanufactured
items are warranted for the remainder of the Warranty Period or ninety
(90) days from shipment, whichever is longer; iv) consumable Supplies
are warranted to conform to published specifications for a period
ending on the expiration date shown on their respective packages;
v) licensed Software is warranted to operate in accordance with
published specifications; vi) Services are warranted to be supplied in
28
Description
NovaSure RF Controller, Model 09
NovaSure RF Controller, Model 10
Power Cord, 115 Volts, North America
Power Cord, 230 Volts, Europe
Power Cord, 220 Volts, United Kingdom/Ireland
Power Cord, Denmark
Power Cord, Italy
Power Cord, Switzerland
Power Cord, Japan
Power Cord, Australia
Foot Switch
CO
(USP), Cylinder 5 Pack
2
NovaSure Impedance Controlled Endometrial
Ablation Disposable Device Kit
NovaSure Kit: 3 NovaSure Impedance Controlled
Endometrial Ablation Disposable Devices packaged
with 3 SureSound devices
Biohazard Kit