Item
Starter relay:
Model/manufacturer
Amperage rating
Coil winding resistance
Starting circuit cut-off relay:
Model/manufacturer
Coil winding resistance
Fuse (amperage × quantity):
Main fuse
Reserve fuse
Part to be tightened
Stator
Holder (AC magneto lead)
Rotor
Neutral switch
Starter motor
Starter relay terminal
Negative lead and cylinder head
All manuals and user guides at all-guides.com
MAINTENANCE SPECIFICATIONS
2768090-A/JIDECO
180 A
4.2 ~ 4.6 Ω at 20 °C (68 °F)
ACM33221 M06/MATSUSHITA
75.69 ~ 92.51 Ω at 20 °C (68 °F)
10 A × 1
10 A × 1
Thread size
M5 × 0.8
M5 × 0.8
M12 × 1.25
M5 × 0.8
M6 × 1.0
M6 × 1.0
M6 × 1.0
2 - 18
SPEC
Standard
Tightening torque
Q'ty
Nm
2
7
2
7
1
85
2
4
2
10
2
4
1
10
Limit
----
----
----
----
----
----
----
m·kg
ft·lb
0.7
5.1
0.7
5.1
8.5
61
0.4
2.9
1.0
7.2
0.4
2.9
1.0
7.2