All manuals and user guides at all-guides.com
SYSTEM DE DEMARRAGE ELECTRIQUE
DIODE INSPECTION
3
2
1. Remove the diode from wire har-
2. Inspect:
1
Tester (+) →
Blue/Red terminal 1
Tester (–) →
Sky blue terminal 2
Tester (+) →
Blue/Red terminal 1
Tester (–) →
Blue/Yellow terminal 3
Tester (+) →
Sky blue terminal 2
Tester (–) →
Blue/Red terminal 1
Tester (+) →
Blue/Yellow terminal 3
Tester (–) →
Blue/Red terminal 1
Incorrect continuity → Replace.
START SWITCH INSPECTION
1. Inspect:
Tester (+) lead → Black lead 1
Tester (–) lead → Black lead 2
PUSH IN
No continuous while being pushed →
Replace.
Continuous while being freed →
Replace.
2. Inspect:
a
ELECTRIC STARTING SYSTEM
ness.
• Diode continuity
Use pocket tester
(tester selection position Ω × 1)
Contin-
uous
Contin-
uous
No con-
tinuous
No con-
tinuous
• Start switch continuity
Tester
B
B
selector
1
2
position
Ω × 1
FREE
• Rubber part a
Tears/damage → Replace.
6 - 33
–
ELEC
INSPECTION DE LA DIODE
1.
Déposer la diode du faisceau de fils.
2.
Contrôler:
• Continuité de la diode
Utiliser le testeur de poche
(position de réglage Ω × 1)
Multimètre (+) →
Borne bleue/rouge 1
Conti-
Multimètre (–) →
nuité
Borne bleu ciel 2
Multimètre (+) →
Borne bleue/rouge 1
Conti-
Multimètre (–) →
nuité
Borne bleue/jaune 3
Multimètre (+) →
Pas de
Borne bleu ciel 2
conti-
Multimètre (–) →
nuité
Borne bleue/rouge 1
Multimètre (+) →
Pas de
Borne bleue/jaune 3
conti-
Multimètre (–) →
nuité
Borne bleue/rouge 1
Mauvaise continuité → Remplacer.
INSPECTION DU CONTACTEUR
DE DEMARRAGE
1.
Contrôler:
• Continuité du contacteur de
démarrage
Fil (+) de multimètre → Fil noir 1
Fil (–) de multimètre → Fil noir 2
Position de
B
B
sélecteur du
1
2
multimètre
ENFONCE
Ω × 1
RELACHE
Pas de continuité lorsqu'enfoncé →
Remplacer.
Continuité lorsque libéré → Remplacer.
2.
Contrôler:
• Pièce en caoutchouc a
Fissures/dommage → Remplacer.
+