10.6.6 change assignment of the end position leDs
Figure 37:
Assignment of the end position LED - AS-Interface
Danger!
risk of electric shock.
▶ Before working on equipment or device, switch off the power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for electrical equipment.
Procedure:
noTe!
Breakage of the pneumatic connection pieces due to rotational impact.
▶ When unscrewing and screwing in the transparent cap, do not hold the actuator of the process valve but the
connection housing.
→
Open the control head: turning the transparent cap anti-clockwise.
Figure 38:
Open control head
→
Using the jumpers, assign the required color to the LEDs (see "Figure 37: Assignment of the end position LED
- AS-Interface").
noTe!
Damage or malfunction due to penetration of dirt and humidity.
▶ To observe degree of protection IP65 / IP67, screw the transparent cap in all the way.
→
Close the device (assembly tool: 674078
The assembly tool (674078) is available from your Bürkert sales office.
46
7)
All manuals and user guides at all-guides.com
End position
LED green
Jumper for
assignment of
end position LEDs
End position
LED yellow
).
7)
english
Top
Bot
ye
ye
gn
gn
Bot
Top
Top
Bot
ye
ye
gn
gn
Bot
Top
Transparent cap
Body casing
Connection housing
Actuator
Type 8695
AS-Interfaceinstallation
Jumper setting 1:
In the end position top
(Top), the yellow LED
is lit; in the end position
bottom (Bot), the green
LED is lit.
Jumper setting 2:
In the end position top
(Top), the green LED is lit;
in the end position bottom
(Bot), the yellow LED is lit.