Type 8695
Installation
→
Push the control head, without turning it, onto the actuator until no gap is visible on the form seal.
noTe!
too high torque when screwing in the fastening screw does not ensure degree of protection ip65 /
ip67.
▶ The fastening screws may be tightened to a maximum torque of 1.5 Nm only.
→
Attach the control head to the actuator using the two side fastening screws. In doing so, tighten the screws
only hand-tight (maximum torque: 1.5 Nm).
Connection
pieces
Pilot air ports
(actuator)
Figure 10:
Installation of control head
All manuals and user guides at all-guides.com
Fastening screws
max. 1.5 Nm
english