6.8
electrical data
Warning!
Only circuits with limited power may be used for UL approved components according to "NEC Class 2".
6.8.1
electrical data without bus control 24 V Dc
Protection class
Connections
Pilot valve
Operating voltage
Power input
Output
Display
6.8.2
electrical data with as-interface bus control
Protection class
Connections
Profile
Operating voltage
Outputs
Max. switching capacity
Watchdog function
Max. power consumption
Power consumption input during
normal operation
(after current reduction;
valve + 1 end position reached)
6.8.3
electrical data with Devicenet bus control
Protection class
Connections
Operating voltage
Max. power consumption
Output
Pull-in current current
Holding current
16
All manuals and user guides at all-guides.com
3 as per DIN EN 61140 (VDE 0140-1)
Circular plug-in connector (M12 x 1, 8-pole)
24 V DC ± 10% - max. residual ripple 10 %
max. 1 W
max. 100 mA per output
max. 20 mA per illustrated illuminated display (LED)
3 as per DIN EN 61140 (VDE 0140-1)
Circular plug-in connector (M12 x 1, 4-pole)
S-B.A.E. (A/B slave, max. 62 slaves/master)
29.5 V – 31.6 V DC (according to specification)
1 W via AS-Interface
integrated
120 mA
90 mA
3 as per DIN EN 61140 (VDE 0140-1)
Circular plug-in connector (M12 x 1, 5-pole)
11 V – 25 V
< 80 mA
≤ 50 mA
≤ 30 mA