Perth 6P - Pelican 6P
English
Preparation
• recover the refrigerant.
• remove the lubricating oil.
Obligations
• dismantle the cabinet in accordance with the local laws on waste disposal and
• according to the legislation in force, the cabinet is considered as dangerous
• take the intact parts of the refrigeration circuit to specialised refrigerant recy-
Liability
the customer or the employer must deliver the cabinet to be dismantled to the
collection centre specified by local authorities or indicated by the manufacturer
for the recovery and recycling of materials.
The cabinet is
Iron tube
made of
Copper, Aluminium
Galvanized plate
Expanded
(CO
Tempered glass
PVC
Polystyrene
Polycarbonate
27. Spare parts
Use only original spare parts
• replace the parts before wearing excessively to avoid damage to persons or property
• carry out scheduled maintenance as provided in the agreement.
The spare parts catalogue can be found at this address: https://globalassistance.arneg.it/
28. Warranty
The Buyer can take advantage of the warranty provided by the supplier only by carefully observing
the instructions given in this manual, in particular if:
• always use within the cabinet's operating limits
• to carefully and continually carry out maintenance operations
• authorises the use of the machine by operators and technicians trained for the purpose and with
proven skills and behaviour (see chap. 4-5-6)
Conditions
Italy: unless otherwise agreed, the machines are guaranteed only if factory
new, for one year from the date of shipment, except for the electrical and rela-
ted parts. Within this period, the parts will be replaced or repaired for free at
the discretion of our technicians that will assess it they are defective. For fur-
ther details on warranty conditions please check the sales terms.
Overseas: see the agreements with the respective dealers or area managers.
i
Failure to comply with the instructions in this manual shall void the warranty.
29. Troubleshooting
Problem
54
respecting the environment in which we live.
waste and falls under the category of separate collection and cannot be treated
as domestic waste or be sent to landfill.
cling centres.
Material
polyurethane
)
2
Possible causes
Components
lower frame
refrigerant circuit, electric system, door frame
motor base, lower panels, varnished panels, base
structure, shelves, trays
thermal insulation
doors
shock absorber
thermoforming panel
fluorescent bulbs protection
Possible solutions
05060216 00 06-2022