The systems must be set up in accordance to the regulati ons that regulate manufacture,
installati on, use, and maintenance foreseen by the norms in force in the country where the
refrigerati on system is installed.
To ensure normal operati on, the maximum voltage variati on must be within +/- 6% of the
nominal value.
Liability
Customer
Installer
Manufac-
turer
Power
• size the power supply lines according to the absorbed power of the cabinet
supply line
• check that the power line:
Automati c
safety switches
• protect the upstream cabinets with omnipolar circuit breakers with suitable
• inform the operator of the positi on of the switches so that they can be reached
Before
connecti ng
• consult the wiring diagrams annexed to the cabinet
• ensure that the rati ng plate data matches the characteristi cs of the electrical
• check that power supply voltage is the one reported on the rati ng plate
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with the connecti on.
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protecti on devices; modify the system to diff erenti ate the start-up
of the various devices.
17. Checking and adjusti ng the temperature
The refrigerati ng temperature is checked via the electronic controller (Fig.13)
i
To change the controller programming, call the manufacturer.
18. Filling the cabinet
48
provide a power line to the cabinet connecti on point.
provide anchoring devices for all cables entering and leaving
the cabinet.
ARNEG S.p.A. denies all liability with respect to the user or third
parti es for:
- damage caused by malfuncti ons of the systems placed up-
stream of the cabinet
- damage caused to the cabinet by malfuncti ons of the electri-
cal system.
indicated on the serial plate chap.9.
- has wires with suitable cross secti on
- is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force
- for power lines longer than 4-5 m use cables with suitable cross-secti on.
i
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorised by the same.
DANGER! Live parts. Short circuit. Electrocuti on
The automati c circuit breaker must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnecti on in conditi ons of
category III overvoltage.
characteristi cs that will also functi on as master switches to secti on off the line
immediately in the event of an EMERGENCY.
DANGER! Live parts. Short circuit. Electrocuti on
Check that the att achments of the lighti ng systems (fl oors, roof, ceil-
ing) are properly inserted and locked into their housings to avoid
disconnecti ons during cleaning and maintenance operati ons, that may
cause harmful electric shocks.