Ramp heating with top layer of stone or paving slabs
60-80 mm
30-50 mm
Ramp heating embedded in concrete / cement screed Top layer asphalt
Concrete / cement
screed ground
If the heating cable can not be fixed to a reinforcement mesh, the installer should use the plastic spacer (for asphalt
metal VIA-SPACER) or other fixing method to keep the cable spacing consistent.
Slab preparation & reinforcement
In the case of a concrete slab, the mesh or reinforcement bar must be ad equately supported so that it is not
disturbed during the concrete pour.
The reinforcement must be positioned so that the heating cable will be 50 mm below the surface of the concrete.
The reinforcement must be positioned at the correct distance below the surface of the concrete to within ± 1 cm.
Where mesh is used, it must be strong enough that it will not "droop" when walked on for the installation of the
heating cable. Use a mesh grid of at least 50 mm. A grid spacing of 100 mm is most practical.
Where a reinforcement bar is used, arrange its spacing to match the requirement of the heating cable spacing.
100-125 mm for
250-300 W/m²
WinterGard Cable
Sand bed
100-125 mm for
250-300 W/m²
WinterGard Cable
Concrete / compacted
substrate
Surface of concrete
50 mm
minimum
Reinforcement support
Temperature and
moisture sensor
Soil ground
Temperature and
Asphalt layer
moisture sensor
25 mm
Heating cable
Mesh
20-30 mm
Stones / paver
(max. 8 cm)
50 mm
Soil
nVent.com/RAYCHEM
EN
DE
FR
PL
CZ
RU
NL
SV
NO
FI
|
15