Type 8691
DeviceNet
Status of the pilot valve LeD
leD
explanation
Off
• Pilot valve is not actuated
Yellow
• Pilot valve is actuated
Table 25:
Status of the pilot valve LED
noTe!
Damage or malfunction due to penetration of dirt and humidity.
To ensure degree of protection IP65 / IP67:
▶ Screw the transparent cap in all the way.
11.13.3 Device status - assignment of the leDs
The device status of the control head (transparent cap) is displayed optically by colored high-power LEDs (Top
LEDs). The assignment of the green and yellow Top LEDs to the end position can be changed via Explicit Mes-
sages (attribute address: class 150, instance 1, attribute 9) or via the communication software.
The following functions are shown as standard
color
green Top LEDs on
yellow Top LEDs off
red LED flashing
alternately with the green or
yellow Top LEDs
Table 26:
Assignment of Top LEDs, DeviceNet
Figure 49:
Top LEDs and status LED, DeviceNet
noTe!
Damage or malfunction due to penetration of dirt and humidity.
To ensure degree of protection IP65 / IP67:
▶ Screw the transparent cap in all the way.
Device status
End position bottom
End position top
• online, without connection to the Master
• Connection time-out
• Critical error
Top LEDs
Status LED
(yellow)
english
57