7.4
Manual operation
(4)
Manual operation LED (8)
Manual operation can be activated using the button (8). The
wastewater pump is no longer switched on automatically.
If manual operation is switched on during the pumping
process, the wastewater pump switches off.
Activate manual operation
Press the button (8), the manual operation LED (4)
flashes orange.
The wastewater pump can be switched on as follows when
manual operation is activated:
Switching on briefly
Press the button (8) 1x.
The wastewater pump will be switched on for a short
period.
Switching on for longer
Press the button (8) and keep it pressed for as long as
the wastewater pump is to be switched on.
The wastewater pump is switched on.
If manual operation is not used for a certain period of time
(5 minutes), the control unit reactivates automatic opera-
tion.
7.5
Switching off the system
Unplug the mains plug for the control unit, wait for a few
seconds until the power outage alarm is activated (short,
repetitive signal tone and the alarm LED (2) flashing)
Press the alarm button (6) and keep it pressed until the
alarm LED (2) no longer flashes, four short signal tones
sound and the control unit is switched off
If the control unit is switched off, the battery connection
is deactivated. The battery can remain connected since
it will not be discharged. Mains voltage is required for ini-
tialisation since this re-activates the battery connection.
34 / 112