Installation
Step 9: Connect Unit to Electrical Power
Stacked Washers and Electric Dryers
Equipped with Lead-In Cord
(120/240 Volt, 60 Hertz, 3-Wire and Ground
Installation)
(120/208 Volt, 60 Hertz, 3-Wire and Ground
Installation)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electrical shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
Canadian Electrical Code, Parts I and II, and
such local regulations as might apply. It is
the customer's responsibility to have the
wiring and fuses installed by a qualified
electrician to make sure adequate electrical
power is available to the unit.
NOTE: Single electrical connection serves both
washer and dryer.
The electric service must be a separate branch,
polarized, three-wire and ground, 120/240 Volt, or
120/208 Volt, 60 Hertz, AC single phase circuit fused
with 40 Ampere fuses.
The cord (supplied with dryer) and plug assembly
(obtain locally) should be plugged into an approved
receptacle that is mounted on the wall adjacent to the
unit. This receptacle should be accessible to the user or
service person when the unit is in position, to permit
disconnecting when necessary.
Stacked Washers and Electric Dryers Not
Equipped with Lead-In Cord
(120/240 Volt, 60 Hertz, 3-Wire and Ground
Installation)
(120/208 Volt, 60 Hertz, 3-Wire and Ground
Installation)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
22
W515
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer's responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
NOTE: Single electrical connection serves both
washer and dryer.
Grounding and Wiring Instructions
1
1
Ground Wire
2
"L1" Terminal
3
Neutral Terminal
4
"L2" Terminal
Figure 17
The dryer must be connected to a grounded metal,
permanent wiring system; or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or
lead on the dryer.
IMPORTANT: DO NOT connect ground wire to
neutral terminal.
W521
2
3
4
DRY2377N
802703