Press T6 key within 30 seconds (programming
time-out). The LED of button T6 is on and flashing.
During this stage and for the entire tea dose
programming time duration, the solenoid valve and the
pump are activated.
If no dose key is pressed
within 30 seconds, it will
automatically escape from
programming mode.
After pressing the T6 key, water dispensing starts.
When the desired tea dose has been reached, press
the T6 key again to stop dispensing the water dose.
This way the new value is saved by the pulses of the
dose. Both the solenoid valve and the pump are
deactivated thereby suspending product brewing. The
LED relating to the programmed key turns off.
Press the T3 key again to immediately exit the
programming stage.
During the programming of
tea the group functioning
and
tea
disabled.
English
brewing
are
31