Wiring; Power And Ground; Power Wiring; Voltage Selection - LiftMaster LOGIC 5.0 T Manuel D'installation

Opérateur de porte commerciale
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WIRING

To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the
operator MUST NOT be performed until disconnecting the
electrical power and locking-out the power. Upon completion of
maintenance the area MUST be cleared and secured, at that
time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with
national and local electrical codes. The operator should be on a
separate fused line of adequate capacity.

POWER AND GROUND

Power and control wiring must be run in separate conduit to
comply with national and local electrical codes. For power wiring,
use the appropriate wire gauge. Use conduit knockouts, conduit
fittings, and appropriate conduit fittings for wiring as indicated
on the electrical box label.
1
Remove the operator cover.
2
Run power wires to electrical box according to national and
local electrical codes.
ON THREE PHASE MACHINES ONLY: Incorrect phasing of
the power supply will cause the motor to rotate in the wrong
direction. To change motor rotation, exchange incoming
power leads L1 and L2.
3
Attach power and ground wires to appropriate terminals.
NOTE: The operator must be properly grounded. Failure to
properly ground the operator could result in electric shock
and serious injury.
POWER WIRING CHART
DISTANCE
50 feet (15.2 m)
100 feet (30.5 m)
200 feet (61 m)
350 feet (106.7 m)
500 feet (152.4 m)
1000 feet (304.8 m)
* Maximum wire gauge that can be connected to the operator's
terminal is 12 AWG. When a larger wire gauge is required, the wire
must be gauged down to 12 AWG. USE COPPER WIRE ONLY.

VOLTAGE SELECTION

For all operators except for 575V 3 Phase operators, follow the
steps below. The motor harness is connected to the power board
at the factory on all 575V 3 Phase operators.
1
Locate motor harness inside of the electrical box.
2
On the POWER BOARD find the appropriate receptacle
matching the incoming line voltage. Remove the voltage
label and apply to the inside of the electrical box for future
reference. Insert the motor harness fully until locked in place.
Wiring
Hot
Neutral
Gnd
GAUGE
14 AWG
12 AWG
8 AWG*
6 AWG*
4 AWG*
2 AWG*
Hot
Neutral
Gnd
• ALL electrical connections MUST be made by a qualified
individual.
• DO NOT install ANY wiring or attempt to run the operator
without consulting the wiring diagram.
• ALL power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
• ALL power and control wiring MUST be run in separately.
1
P/N: 40- 10031.EP S
DESCRIPTION: POWER WIRING (ELEC BOX. CONDUIT A
SIZE: 2.50 X 0.50
MATERIAL & ART WORK: SEE SPECIFICATION DRAWING
3
Single Phase Power Wiring
Line Power
115/230 Vac
Single Phase
Three Phase Power Wiring
Line Power
208/230/460/575 Vac
Three Phase

POWER WIRING

USE COPPER WIRE ONLY
SINGLE PHASE POWER BOARD
Motor
Harness
P/ N : 40-10032B.EPS
D ESCRIPTION: CONTROL WIRING ( ELEC BOX. CONDUIT AC
SI ZE: 2.50 X 0.50
MATERIAL & ARTWORK: SEE SPECIFICATION DRAWING 4 0
Fusing on the 3-Phase Power Board is not field-replaceable. An
Open Fuse indicates that the 3-Phase Power Board is damaged
and must be replaced. Failure to replace the complete 3-Phase
Power Board may result in additional damage to the Operator.
19
Hot
Neutral
Gnd
2
Hot
Neutral
Ground
Ground
Phase 1
Phase 2
Phase 3
Ground
40-10031B
P / N : 40-1 0031.E P S
D ESC RI PTI O N: P OWER WI RI NG (E LEC B OX . C ON DUI T AC CE S S H O LE )
SI ZE: 2. 50 X 0.50
Hot
M ATE RI AL & ARTWO RK : SE E SP ECI FI CATIO N DR AW I NG 40-1003 1
Neutral
Gnd
POWER WIRING
USE COPPER WIRE ONLY
40-10 031B
P/ N: 40- 10032B .E PS
DE SCR IP TIO N : CO NTRO L WI RI NG ( ELE C BOX . CO ND UI T ACC E S S HO L E )
S IZE : 2.5 0 X 0. 50
M ATERI AL & ARTWO RK: S EE S PEC IFI C ATI O N DRAW IN G 40-10032
S CA L E D 2:1

Publicité

Table des Matières
loading

Table des Matières