CONTROL STATION
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing the door
control.
To prevent possible SERIOUS INJURY or DEATH from a closing
door:
• Install the door control within sight of the door, out of reach of
small children, at a minimum height of 5 feet (1.5 m) above
landings, steps, or any other adjacent walking surface, and
away from ALL moving parts of the door.
• Install the control station far enough from the door to prevent
NOTE: The low voltage control circuit wiring requires insulated,
20 AWG or heavier wire. Refer to the back page of this manual for
additional control wiring information.
1
Remove the control station cover.
2
Fasten the control station to the wall at least 5 feet (1.5 m)
above floors, landings, steps, or any other adjacent walking
surface. The installation surface must be smooth and flat .
Attach the MAS label to the side of the control station.
3
5'
(1.5 m)
5
1
^
O P
E N
O
S T
O P
2
UL Entrapment Placard
MAS Label
the user from coming in contact with the door while operating
the controls.
• Install the entrapment warning placard on the wall next to the
control station in a prominent location visible from the door.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
• Activate a door ONLY when it can be seen clearly, is properly
adjusted and no obstructions exists in the path the door will
travel.
• ALWAYS keep the door in sight until completely closed.
NEVER permit anyone to cross path of a closing door.
3
Select the appropriate knockout and run the wires to the
operator (in accordance with national and local electrical codes).
4
Connect wires to the control station and replace the control
station cover.
5
Fasten the entrapment warning placard next to the control
station.
4
20
LED
3-Button
Station
Maintenance
Alert LED
(RD)
(WH)
Open
Close
Stop
Wiring