PROGRAMMING REMOTE CONTROLS

Built in 3-channel, Security+ 2.0
NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) Device.
STANDARD REMOTE CONTROL
1. To enter programming press and release the RADIO button on
the logic board (RADIO LED will light).
2. Press and hold the remote control button until the RADIO LED
flashes rapidly, then release remote control button. The RADIO
LED will then remain on solid after releasing the button. Repeat
to add additional remote control(s).
3. Press and release the RADIO button to complete the
programming. The RADIO programming mode will exit if no
activity is performed within 30 seconds. The MAS and RADIO
LED's will flash briefly to indicate the RADIO has exited the
programming mode for remote controls and keyless entry
devices. The RADIO will remain in program mode for another
150 seconds for myQ devices and then will completely exit with
no activity.
radio receiver, up to 90 remote control devices and up to 30 keyless entry devices can be added.
®
SINGLE BUTTON REMOTE CONTROL PROGRAMMED AS
A SINGLE BUTTON CONTROL (SBC)
This function programs a remote control as a wireless single
button control. This function will work in the following modes:
In B2 mode, operation is OPEN/STOP/CLOSE/REVERSE/STOP.
In T and TS modes, operation is OPEN/STOP/CLOSE/REVERSE/
STOP and Timer-To-Close start/refresh. NOTE: If Car Dealer
mode is enabled, SBC will be open only, stopping at the Open
Mid-Stop.
In FSTS mode, operation is OPEN with Timer-To-Close
start/refresh only, bypassing a programmed Open Mid-Stop.
1. Press and release the RADIO button on the logic board
(RADIO LED will light).
2. Press and release the SBC externally wired button. The RADIO
LED flashes rapidly and remains on solid. (If an SBC externally
wired button is not present, a jumper wire may be used to
momentarily short SBC and COMMON)
3. Press and hold the remote control button until the RADIO LED
flashes rapidly. The RADIO LED will then remain on solid after
releasing.
4. Press and release the RADIO button on the logic board (RADIO
LED flashes rapidly and then turns off). The programming
mode is exited if no activity is performed within 30 seconds.
The MAS and RADIO LED's will flash briefly to indicate the
RADIO has exited the programming mode for remote controls
and keyless entry devices. The RADIO will remain in program
mode for another 150 seconds for myQ devices and then will
completely exit with no activity.
NOTE: Single button remote control is not supported with D1 and
E2 wiring modes. C2 mode will only open and stop while opening.