CONTROL CONNECTION DIAGRAM
IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
STANDARD
7
6
10
(RED)
Open
Maintenance
Alert LED
Close
Stop
(WHITE)
7
6
Open
Close
TIMER DEFEAT SWITCH
11 12
Keyswitch
NON-MONITORED EDGE SENSOR TO REVERSE OR STOP
NOTE: 11 and 4 are both the same common. Either is acceptable.
01-39130D
4
5
(RED)
Maintenance
Alert LED
(WHITE)
NOTE: Stop circuit must be wired in series for all stop
buttons to function. This may require removal of factory
installed jumper bar in the 3-button station.
2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
4
STANDARD
D1 & E2
MODE ONLY
See note 2.
1 BUTTON STATION OR ANY AUXILIARY DEVICE
OPEN / CLOSE
1
4
B2, T, TS & FSTS
11
8
Edge Sensor
Wi-Fi® is a trademark of Wi-Fi Alliance®
App Store and the Apple and App Store logos are trademarks of Apple Inc.
Google Play and the Google Play logo are trademarks of Google LLC
2 OR MORE
7
6
4
5
10
Open
Open
Close
Close
Stop
Stop
7
MODE ONLY
See note 2.
Remove Factory Installed Jumper when Interlock is Used
2
© 2022, LiftMaster
All Rights Reserved
KEY LOCKOUT
(RED)
Maintenance
Alert LED
(WHITE)
2 OR MORE
6
4
Open
Open
Close
Close
RADIO CONTROLS
(WH) (OR) (YE)
EXTERNAL
R1
R2
R3
RADIO RECEIVER
NOTE: 32 Vdc power supplied from white and yellow
wires located within the electrical box.
EXTERNAL INTERLOCK
3
ONE
All Wiring Types
7
6
4
5
10
Open
Close
Stop
Keyswitch
D1 & E2
MODE ONLY
See note 2.
2
3
2 OR MORE