Parameter
The password-protected area. Settings can be made on the device in this menu point which
have effects on the device properties and functions (e.g. welder code, scan site-code, traceabil-
ity, ...). Entries and functions can be enabled or disabled for the user and therefore sequences
prescribed at the construction site. The PIN code is pre-allocated on the works side with
"12345". Please alter the password as needed (see sub-menu point "Password"). The menu can
be left at any point using the >END< button.
Welder code
Entry of the welder code can be activated or deactivated here (for a description see Chapter
7.3). The status can be altered by pressing the >CHANGE< button.
If the option "Welder code" is activated then a valid welder code according to ISO-12176-3 is
needed to start a welding sequence.
Traceability Fitting
Entry of the traceability of the fitting can be activated or deactivated here or set as an optional
entry (for a description see Chapter 7.3). The status can be altered by pressing the >CHANGE<
button.
Traceability Pipes
Entry of the traceability of the pipes can be activated or deactivated here or set as an optional
entry (for a description see Chapter 7.3). The status can be altered by pressing the >CHANGE<
button.
Owner
The owner of the device (e.g. the company name) can be altered here. The change takes place
manually (see also the Chapter "Data entry").
Erase ALL Logs
This where all stored welding sequences can be deleted.
Attention! The whole memory is deleted. Partial deletion of the stored welding se-
quences is not possible.
The device saves up to 2,000 welding sequences automatically. If the 2,000 memory places are
filled up the device displays an appropriate warning on the Start screen. A further 47 welding
sequences are stored in the overflow memory.
Attention! Loss of data can occur if a welding sequence is performed despite a full
memory. We recommend backing up the logs in good time using a USB stick and
clearing the device memory regularly.
ENGLISH
29