Technical Data
Art.no. ROFUSE 400 / 1200 Turbo ................... 1000000999 / 1000001000
Mains voltage ................................................... 230 V
Frequency ........................................................ 50 Hz; 60 Hz
Power consumption .......................................... 3.000 VA, 70 % ED
Output current (nominal current) ....................... 80 A
Welding voltage ................................................ 8 – 48 V
Ambient temperature ........................................ - 20 °C until + 60 °C*
Area of application ROFUSE 400 Turbo ..........
Arbei
sbereich
t
Protection type .................................................. IP 54
Transmission interface ...................................... USB v 2.0
Storage capacity ............................................... 2.000 Welding logs
Overflow memory .............................................. 47 Welding logs
Dimensions (L x W x H) .................................... about 500 x 250 x 320 mm
Weight including welder cable
(basic unit, without accessories) ....................... about 21,5 kg
Contacts ........................................................... 4 mm and 4.7 mm according to IEC 60529
*Cooling times vary with the ambient temperature. Direct sunlight should be avoided
2.1
Measurement tolerances
Temperature ..................................................... ± 5 %
Voltage ............................................................. ± 2 %
Current ............................................................. ± 2 %
Resistance ........................................................ ± 5 %
3
Active Cooling System (ACS) and Heat Control (HC)
The device is fitted with a ventilator. This starts up as soon as the device is switched on at the
main switch. The fan assists in better removing the heat which arises in the device during weld-
ing. We recommend therefore that the device is also switched off between two welding sessions
in order to optimise cooling of the device.
The device is fitted with a heat control function (HC). Before every welding session the device
decides whether the next welding session can be reliably performed to the end. Factors such as
the current device temperature, the ambient temperature and the welding data of the fittings play
a role. If the current device temperature is too high, the expected waiting time is displayed on
the display. The ventilator reduces this waiting time significantly.
4
Storage / transport
The device power connecting cable and the welding cable should be protected from sharp edg-
es.
The welding device should not be subjected to strong mechanical loads.
The device should be stored at temperatures ranging from - 30 to + 70°C.
5
Work preparation
When operating the automatic welding machine ensure that it is installed on a sure footing. The
welding device is splash proof (IP54).
ROFUSE 1200 Turbo ..........
Fittings until 400 mm
Fittings until 1200 mm