Télécharger Imprimer la page

AQUALUX Orchidee Manuel D'instructions page 70

Publicité

Les langues disponibles

Les langues disponibles

Check the water level.
Check the water temperature with an accurate thermometer.
Remove the spa cover and allow the water to cool to below 42°C (if
necessary, add cold water). Press any button to re-initialize the system. If
the water temperature is still hotter than the pre-set temperature, press the
blower button (if the spa is fitted with a blower) to cool the spa.
If the problem is repeated, test the sensor assembly.
faulty
faulty. The sensor connected to connector plug "A" or "B", depending on the message, is
faulty
faulty
not operating.
If the problem reoccurs, test the sensor assembly or contact your spa dealer or
repairer.
Remark:
Remark: In rare cases, rapid overheating of the system causes sensor error messages.
Remark:
Remark:
Make sure that there are no conditions such as lack of pressure or water.
This message indicates that the sensors are unbalanced. When the
temperature readings are not the same, this may be a temporary
condition. If this message flashes on its own, the spa stops.
If the panel also displays
Stopping of the spa following this error means that the sensor reading is probably
maladjusted by a few degrees. If the problem is repeated, test the sensor assembly. If the
problem continues, contact your spa dealer or repairer.
This indicates that the sensor has detected a possibility of freezing
a standard function of the spa: no corrective action is necessary. When the system
indicates a temperature less than 4.5°C, the system provides protection against freezing.
If only pump 1 starts for this reason, this message is displayed for more than 2 minutes
after the detection of very cold water.
Remark:
Remark: internal protection against freezing only operates when the spa voltage is
Remark:
Remark:
correct and the control system is operational.
"Ice": This means that the auxiliary sensor has detected a possibility of
freezing. This is a standard function of the spa: no corrective action is necessary.
freezing.
freezing.
freezing.
When the auxiliary sensor reading is around 4°C, the system activates freezing
protection. It automatically starts all the pumps and the blower to circulate the water
and heat the pipelines, whatever the status of the bath.
"Service Reqd"
"Service Reqd"
"Service Reqd"
"Service Reqd"
the spa stops.
These two messages indicate that the spa
has stopped because the sensor is open or
a possibility of freezing. This is
a possibility of freezing
a possibility of freezing
32
sensor is open or
sensor is open or
sensor is open or
a possibility of
a possibility of
a possibility of

Publicité

loading

Produits Connexes pour AQUALUX Orchidee