Once the pumps have started, press the "Jets 1" and "Jets 2" keys to stop and manually
exit initiation mode by pressing the "High" or "Low" keys.
Note that if you do not manually exit initiation mode, it will finish automatically after 4
minutes.
However the initiation mode is exited, automatically or manually, the system then
automatically returns to standard heating and filtration mode. The default spa filtration
cycle program is 2h. To modify this setting, please refer to the "Programming filtration
cycles" section.
After exiting the initiation mode, the screen momentarily displays the pre-set
temperature, then dashes.
Note that the screen does not display the actual temperature of the water in the bath.
This is because the system needs the water to pass through the heating device for
approximately two minutes to determine its temperature.
After 2 minutes, the actual temperature of the water in the bath is displayed. Press the
"High" or "Low" keys to adjust the set temperature to the desired level. If the actual
temperature is less than the set temperature, the heating indicator comes on, indicating
that the heater has started operating.
Once the system is powered and the pumps have started, make a final check on the
voltage at the terminal.
Start pump 1 at low speed (this action cannot be carried out during the first
•
6 minutes after powering).
Adjust the temperature to start the heating operation.
•
Switch on the lighting
•
Check the voltage that for 230V systems should be between 207 and 253 V
•
between live and neutral. If the voltage is not between these ranges check
the cross section of the cables used. If the cross section is correct, contact
your electrician.
Remark: If the voltage is outside tolerances while the system is operating correctly, cut
Remark:
Remark:
Remark:
off the power supply at the main panel and fix the problem before restarting system
operation.
14