Feed the power supply cable through the unit grommet provided for this
•
purpose. The permissible diameter for the power supply cable to pass
through the unit grommet is between 13mm and 21mm.
Use a flexible PVC/PVC insulated 500Vcopper power supply cable (not
•
supplied), 3G2.5 mm
link between the circuit breaker and the spa (for long distances, ask your
electrician about cable sizing).
Connect the 230Vac 16A single phase power supply to the L1 and
•
N1terminals.
Connect the earth to the external terminal of the unit provided for this
•
purpose.
Connect the power supply cable of your spa to a 16A PH + N circuit
•
breaker on your electrical power supply panel.
A 30mA differential protection is to be scheduled if not already present, or
•
undersized on your home electrical power supply panel.
Your spa can operate without shedding at 32A. In this operating mode, you can operate
the heater, pumps and blower simultaneously.
Remove the access panel on the digital control side, which opens the spa
•
control
Ensure that switch 10 of the Switchbank connector in the electrical unit is in
•
the OFF position. (down).
Feed the power supply cable through the unit grommet provided for this
•
purpose. The permissible diameter for the power supply cable to pass
through the unit grommet is between 13mm and 21mm.
Use a flexible PVC/PVC insulated 500Vcopper power supply cable (not
•
supplied), 3G6 mm2 minimum, in a sheath adapted to ensure the electrical
link between the circuit breaker and the spa (for long distances, ask your
electrician about cable sizing).
Connect the 230Vac 32A single phase power supply to the L1 and
•
N1terminals.
Connect the earth to the external terminal of the unit provided for this
•
purpose.
Connect the power supply cable of your spa to a 32A PH + N circuit
•
breaker on your electrical power supply panel.
2
minimum, in a sheath adapted to ensure the electrical
5.1.2. Installation without shedding at 32A