A 30mA differential protection is to be scheduled if not already present, or
undersized on your home electrical power supply panel.
5.2. Connection to 2x16A three-phase network
If your electricity network is three-phase, it is possible to connect your spa in a 2PH
16A+N configuration. This enables distribution of power over 2 different phases.
Remove the access panel on the digital control side, which opens the spa
control.
The jumper connected between the J32 and J26 connectors must be
removed. . . .
removed
removed
removed
Ensure that switch 10 of the Switchbank connector in the electrical unit is in
the ON position. (up).
Feed the power supply cable through the unit grommet provided for this
purpose. The permissible diameter for the power supply cable to pass
through the unit grommet is between 13mm and 21mm.
Use a flexible PVC/PVC insulated 500Vcopper power supply cable (not
supplied), 5G2.5 mm2 minimum, in a sheath adapted to ensure the electrical
link between the circuit breaker and the spa (for long distances, ask your
electrician about cable sizing).
Connect the 230Vac 16A single-phase power supply to the L1 and N1
terminals (this electrical power supply only concerns the heater).
Connect the 230Vac 16A single-phase power supply to the L2 and N2
terminals (this is the electrical power supply for all equipment except the
heater).
10
J32
J26
must be
must be
must be