2. Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of
the slave light. Connect the DMX OUT socket of the master and the DMX IN socket of the slave light,
then, connect the OUT socket to the IN socket of the next light. Ordinal to connect all the lights as
below:
A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR
connector with a 120Ω resistor between the pin 2 and pin 3 of the XLR connector
DMX IN
POWER IN
Signal (-)
Signal (+)
CONTROL PANEL
LCD DISPLAY
Use Menu button to choose a function. Press Enter button to enter the menu of the selected func-
tion. Use the Up and Down buttons to select the parameters, then press Enter button to confirm
the selected parameter
Check the following function table :
MENU
DMX addr
A001-AXXX
Auto run
Auto Play
Music run
ALL reset
Reset
Scan reset
Other reset
Reverse Pan
On/Off
ReversTilt
On/Off
Special
Reset Default
Calibrat
Temperatur
Manual Crtl
Mic SET
EN
4
2
1
1
Ground
3
DMX512 OUT
DMX512 IN
MENU
UP
DOWN
ENTER
Internal Program 1-9 Master/Alone
Internal Program 1-9 Master/Alone
On/Off
On/Off
On/Off
On/Off
Code (password: 088)
PAN, TILT, ZOOM
XXX°C/°F
PAN=XXX......
0-99%
Signal (-)
Signal (+)
2
3
120 Ω
Description
DMX address setting
Auto Program
Music control
ALL reset
Scan reset
Zoom Reset
Reverse Pan
Reverse Tilt
Reset Default
Calibration code
Calibration of the channel
Current temperature
Manual control
Sensitivity of mic
© Copyright LOTRONIC 2022