Switching Off - Beretta Mynute Sinthesi 25 C.S.I. Manuel De L'installateur Et De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
3A SWITCHING OFF
Temporary switch-off
In the event of absence for short periods of time, set the function selector
to
OFF (fig.34).
In this way (leaving the electricity and fuel supplies enabled), the boiler
is protected by the following systems:
- Heating anti-freeze: this function is activated if the temperature
measured by the delivery probe drops below 5°C. In this phase, the
circulator is activated. If the boiler is not in lockout, the burner is also
activated at minimum output until the delivery water temperature
reaches 35°C.
During the anti-freeze cycle, the symbol
digital display.
- DHW anti-freeze: the function is activated if the temperature
measured by the domestic water probe drops below 5°C. In this
phase, the circulator is activated. If the boiler is not in lockout, the
burner is also activated at minimum output until the delivery water
temperature reaches 55°C.
During the anti-freeze cycle, the symbol
digital display.
- Circulator anti-blocking: an operation cycle is activated every 24 hours
after the last heat request.
Switching off for long periods
In the event of absence for long periods of time, set the function selector
to
OFF (fig.34).
Turn the main system switch OFF.
Close the fuel and water taps of the heating and domestic hot water
system.
In this case, anti-freeze device is deactivated: empty the systems,
in case of risk of frost.
4A CHECKS
Make sure at the beginning of the heating period and during use that
the water pressure gauge indicates the pressure values with cold ap-
pliance comprised between 0.6 and 1.5 bar: this avoids system noise
levels due to the presence of air.
In case of insufficient water circulation, the boiler will switch off. Under
no circumstances, water pressure must be below 0.5 bar (red field).
If this condition is checked, it is necessary to restore water pressure in
the boiler proceeding as follows:
- turn the function selector to
- turn on the filling tap (B - fig. 22) until the pressure value is between
1 and 1.5 bar.
Carefully close the tap.
Replace the mode selector on the initial position.
If pressure drop is frequent, contact the Technical Assistance Service.
5A OPERATING STATUS AND FAULTS
The operating status of the boiler is shown on the digital display. The
types of message are listed below
Boiler status
Stand-by
OFF status
ACF alarm lockout module
ACF electronics fault alarm
Limit thermostat alarm
Air pressure switch alarm
Water pressure switch alarm
Anti-overflow pressure switch
alarm
Reed sensor
(if the "Condense neutralizer
tray" kit is installed)
NTC domestic water fault
NTC heating fault
Parasite flame
Temporary, pending ignition
All manuals and user guides at all-guides.com
(fig. 35) appears on the
(fig. 35) appears on the
(OFF - fig. 34)
Display
Type of alarm
-
Signal
OFF
None
Definitive lockout
A01
Definitive lockout
A02
Definitive lockout
A03
Definitive lockout
A04
Signal
A06
Temporary stop
A07
Temporary stop
A11
80°C
Temporary stop
flashing
Boiler status
Air pressure switch
intervention
Water pressure switch
intervention
Calibration
Preheating active function
Preheating heat request
External probe presence
Domestic water heat request
Heat request for heating
Antifreeze heat request
Flame present
Reset function
To restore operation (reset alarms):
Faults A01-02-03
Turn the function selector to
turn it to the required position.
If the reset attempts do not reactivate the boiler, request the intervention
of the Technical Assistance Centre.
Fault A04
In addition to the fault code, the digital display displays the symbol
in the following cases:
- Insufficient water pressure
Check the pressure value indicated by the water gauge:
if it is less than 0.3 bar, position the function selector on
adjust the filling tap until the pressure reaches a value between 1
and 1.5 bar.
Then turn the function selector to the required position.
If pressure drops are frequent, request the intervention of the
Technical Assistance Centre.
- Anti-overflow pressure switch
Position the mode selector on
then turn it to the required position.
If the fault persists, contact the Technical Assistance Centre.
- Full basin (if the "Condense neutralizer tray" kit is installed)
Remove the basin and empty it, following the instructions supplied
with the "Condense neutralizer tray" kit (available upon request).
Once the operations have been completed, replace the tray.
Position the mode selector on
then turn it to the required position.
If the fault persists, contact the Technical Assistance Centre.
Fault A06
The boiler functions normally but does not guarantee a constant
domestic hot water temperature, which remains set at around 50°C.
The intervention of the Technical Assistance Service is required.
Fault A07
Contact the Technical Assistance Centre.
6A REDUCED CONDENSATION FORMATION - (FIG. 33)
Positioning the adjusting DHW and CH temperature selector to the
"FCR" (reduced condensation formation) zone, the highest delivery
temperatures will be selected.
Mynute Sinthesi C.S.I.
Display
Type of alarm
Temporary stop
flashing
Temporary stop
flashing
Signal
ADJ
Signal
Signal
flashing
Signal
60°C
Signal
80°C
Signal
Signal
Signal
OFF (fig. 34), wait 5-6 seconds, then
OFF and
(OFF), wait for 5-6 seconds and
(OFF), wait for 5-6 seconds and
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mynute sinthesi 29 c.s.i.

Table des Matières